Multitester - wattmeter V-A-P-F-COSfi meter PZEM022
TI7720311
Multitester - wattmeter V-A-P-F-COSfi meter PZEM022
Product parameters:
- measurement of electrical parameters (voltage, current, active power, energy, frequency, power factor)
- overload alarm above adjustable threshold value - flashing alarm and backlight
- the measured energy can be reset using the button
- storable data after shutdown
- all data on the backlit LCD display - the backlight can be turned off
Technical parameters:
- working and measured voltage: 80 ~ 260VAC
- measured current: AC 0–100A / 22000W contactless
- operating frequency: 45–65Hz
- measurement accuracy: grade 1.0
- dimensions: 90×50×20mm
Display:
Power
range: 0.2~22000W
<10W display format: 0.00 ~ 9.99W
<100W display format: 10.0~99.9W
<1000W: 100~999W
<10000W display format: 1.00 ~ 9.90 kW
>10000W display format: 10.0 ~ 22.0kW
Energy
range: 0 ~ 999 kWh
<1kWh display format: 0 ~ 999Wh
<10kWh display format: 1.00 ~ 9.99kWh
>10kWh display format: 10 ~ 999kWh
Tension
range: 80~260VAC
display format: 80 ~ 260V
Current
range: 0.001~100AAC
<10A display format: 0.000 ~ 9.999A
>10A display format: 10.00 ~ 99.99A
Frequency
range: 45~65Hz
display format: 45~65Hz
Power factor
range: 0~1PF
display format: 0.00~1.00PF
Settings:
Power reset
- hold the button until the energy value flashes, then release. Briefly press the button to reset the value on the display.
Setting the alarm threshold
- hold the button until "SET CLr" appears on the LCD display. Then release.
- the display shows the current alarm value. The last digit starts flashing. By repeatedly pressing the button briefly, the alarm value can be changed.
- after completing the setting, press the button for 5 seconds to save. The active energy threshold range is 0.0~2.5kW.
Notice:
- this module is only suitable for indoor use.
- the applied load must not exceed the rated power
- observe the wiring according to the diagram on the back of the product